Keysight (Agilent) 8340A REPAIR and Keysight (Agilent) 8340A CALIBRATION

 
Custom-Cal has a high success rate in the repair of the Keysight (Agilent) 8340A. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 8340A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Signal Generator?
Shop for Comparable Products on our
 used Signal Generator page

 
   Keysight (Agilent) 8340A   Description / Specification:    
Keysight (Agilent) 8340A 26.5 GHz Synthesized Sweeper

The HP 8340A synthesized sweeper deliver the combined high-performance of a synthesizer and a broadband sweep oscillator in one efficient instrument that is completely controllable via the Hewlett-Packard Interface Bus (HP-IB). The synthesized broadband frequency coverage (10 MHz to 26.5 GHz and the precise 1 to 4 Hz frequency resolution (depending on the frequency band of the HP 8340A) are generated by indirect synthesis techniques. The HP 8340A also feature CW switching times of better than 50 ms (typically <35 ms). Additionally, a "Fast phase-lock" programming command can be used to reduce typical CW switching times to between 11 and 22 ms (depending on frequency step size and absolute frequency value). Analog sweep widths as narrow as 100 Hz or as broad as the full frequency range of the HP 8340A permit rapid and thorough testing of any device within their broad frequency ranges. The high performance pulse modulators of the HP 8340A offer >80 dB ON/ OFF ratio and <25 ns rise and fall times. Pulse amplitudes are leveled for pulse widths as narrow as 100 ns. The HP 8340A also features dc-coupled AM modulation with a 3 dB bandwidth of 100 kHz and a minimum depth of 90%. Pulse and amplitude modulation can be used simultaneously to simulate antenna scan patterns. Specifications. CW Mode Frequency Range: 10 MHz to 26.5 GHz. Time Base: Internal 10 MHz time base. Switching time: <50 ms to be within specified frequency resolution (PEAK function off), (Fast Phase Lock Mode reduces typical switching time to <20 ms). Start/Stop Frequency Range: 10 MHz to 26.4999999 GHz (Start); 10.0001 MHz to 26.5 GHz (Stop). Option 001: Front Panel RF Output Without Attenuator. Option 004: Rear Panel RF Output With Attenuator. Option 005: Rear Panel RF Output Without Attenuator. Option 006: Delete Pulse Modulation. Option 007: Relaxed Phase Noise Specifications.



 

Standard Calibration $665.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 8340A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Average Power
Average power means that the energy transfer rate is to be averaged over many periods of the lowest frequency involved. For a CW signal, the lowest frequency and highest frequency are the same, so average power and power are the same. For an amplitude modulated wave, the power must be averaged over many periods of the modulation component of the signal as well.

Dynamic range
Dynamic range the ratio of a specified maximum level of a parameter, such as power, current, voltage or frequency, to the minimum detectable value of that parameter.

Modulation
Modulation is the process by which the characteristic of one wave (the carrier) is modified by another.

Repeatability
Repeatability is the variation in a number of repeated measured quantities when measurement conditions are changed and restored. The value corresponds to half the spread between the minimum and maximum value measured.


Please contact us for your Keysight (Agilent) 8340A REPAIR and/or Keysight (Agilent) 8340A 26.5 GHz Synthesized Sweeper CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: