Keysight (Agilent) 83495A REPAIR and Keysight (Agilent) 83495A CALIBRATION

 
Custom-Cal has a high success rate in the repair of the Keysight (Agilent) 83495A. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 83495A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Fiber Optic Instrumentation?
Shop for Comparable Products on our
 used Fiber Optic Instrumentation page

 
   Keysight (Agilent) 83495A   Description / Specification:    
Keysight (Agilent) 83495A Clock Recovery Plug-in Module

The Agilent 83495A is a clock recovery plug-in module for the Agilent 86100 Infiniium DCA (Digital Communications Analyzer) mainframe. When a separate trigger is not available, or when standards specify that a trigger be derived using a clock recovery unit, the 83495A can be used to obtain a timing reference directly from the signal under test. Channel Type: Single Mode (Multimode Option 101) Optical & Electrical. Clock Recovery Phase Locked Loop Bandwidth: <=100 KHz or <=4 MHz (3.5 MHz typical) user selectable (Internal Path Triggering or External Output). Data Rates (Gb/s): 9.953 to 11.32. Tracking/Acquisition Range: Continuous within data rate range. Internal Splitter: 20/80 (30/70 option 101). Output Jitter: 0.01 UI (0.007 UI typical) RMS. Input Power for Clock Recovery: -11 dBm to +1 dBm optical, 0.10 to 2.0 Vp-p electrical (-8 dBm to +1 dBm optical, 0.10 to 2.0 Vp-p electrical, option 101). Auxiliary Recovered Clock and Regenerated Data Outputs: Type N with SMA adapters (no data output). Input Return Loss: 32 dB (28 dB option 101) maximum optical, DC to 2.5 GHz, 20 dB electrical, 2.5 GHz to 11.32 GHz, 15 dB electrical. Input Insertion Loss: 2.5 dB (3.0 dB option 101) maximum optical.



 

Standard Calibration $945.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 83495A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Optical Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Coherence Length
Average distance over which superimposed waves lose their phase relationships

Linewidth
Linewidth is the width of a spectral line in terms of wavelength, wave number and frequency.

Power Flatness Versus Wavelength
When changing the wavelength at constant power setting and recording the differences between actual and displayed power levels, the power flatness is ± half the span (in dB) between the maximum and the minimum of the measured power levels.

Spectral Width
Spectral Width is the wavelength interval over which the magnitude of all spectral components is equal to or greater than a specified fraction of the magnitude of the component having the maximum value. In optical communications applications, the usual method of specifying spectral width is the full width at half maximum. This is the same convention used in bandwidth, defined as the frequency range where power drops by less than half (at most -3 dB).

Telecom Bands
Optical fiber communications typically operate in a wavelength region corresponding to one of the following Bands. O Band (original): 1260–1360 nm. E Band (extended): 1360–1460 nm. S Band (short wavelengths): 1460–1530 nm. C Band (conventional): 1530–1565 nm. L Band (long wavelengths): 1565–1625 nm. U Band (ultralong wavelengths): 1625–1675 nm


Please contact us for your Keysight (Agilent) 83495A REPAIR and/or Keysight (Agilent) 83495A Clock Recovery Plug-in Module CALIBRATION

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*