Keysight (Agilent) 8350B CALIBRATION and Keysight (Agilent) 8350B REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 8350B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Signal Generator?
Shop for Comparable Products on our
 used Signal Generator page

 
   Keysight (Agilent) 8350B   Description / Specification:    
Keysight (Agilent) 8350B Sweep Oscillator Mainframe

The 8350B Sweep Oscillator Mainframe accepts the 86200 series plug-ins via the 11869A Adapter as well as the wideband 83500 series plug-ins. In order to aid system set ups, the 8350B is directly compatible with the HP 8410C and HP 8756A network analyzers. The frequency accuracy is easily enhanced when the HP 5343A Counter is used to count the START, STOP, or ACTIVE MARKER frequency. For even more frequency accuracy and stability the HP 5344S Source Synchronizer may be used to phase-lock the RF output. The 8350B has three methods of changing function values; control knobs, keyboard entry, or step key entry. The traditional control knob provides an analog "feel" of control which is useful for continuous parameter adjustment. Numerical keyboard entry allows for fast, accurate input. Finally, quantized inputs are possible with step keys. The HP 8350B makes "simultaneous" comparison of two separate frequency ranges or power levels easy via the alternate sweep mode. Specifications. Range: determined by RF plug-in unit used. START /STOP sweep: sweeps up from the START frequency to the STOP frequency. Sweep and Trigger Modes; Internal: sweep recurs automatically. Line: sweep triggered by ac power line frequency. External trigger: sweep is actuated by external trigger signal. Single: selects mode and triggers a single sweep. Sweep time: continuously adjustable from 10 msec to 100 seconds. Manual sweep: front panel controls provide continuous manual adjustment of frequency between end frequencies. External sweep: sweep is controlled by external signal applied to front or rear panel SWP OUTPUT /SWP INPUT connector. Sweep output: direct-coupled sawtooth, zero to approximately ± 10 volts, at front or rear panel concurrent with swept RF output. Save n/recall n: up to 9 different front panel settings can be stored in the 8350B via the Save n (n = I through 9) function. Settings can be recalled randomly or in sequence. Remote Programming (HP-IB): both input and output capability. Options. 400: 400 Hz Power Line Frequency Operation.



 

Standard Calibration $245.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 8350B. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Average Power
Average power means that the energy transfer rate is to be averaged over many periods of the lowest frequency involved. For a CW signal, the lowest frequency and highest frequency are the same, so average power and power are the same. For an amplitude modulated wave, the power must be averaged over many periods of the modulation component of the signal as well.

Dynamic range
Dynamic range the ratio of a specified maximum level of a parameter, such as power, current, voltage or frequency, to the minimum detectable value of that parameter.

Modulation
Modulation is the process by which the characteristic of one wave (the carrier) is modified by another.

Repeatability
Repeatability is the variation in a number of repeated measured quantities when measurement conditions are changed and restored. The value corresponds to half the spread between the minimum and maximum value measured.


Please contact us for your Keysight (Agilent) 8350B CALIBRATION and/or Keysight (Agilent) 8350B Sweep Oscillator Mainframe REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: