Keysight (Agilent) 83622A CALIBRATION and Keysight (Agilent) 83622A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 83622A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Signal Generator?
Shop for Comparable Products on our
 used Signal Generator page

 
   Keysight (Agilent) 83622A   Description / Specification:    
Keysight (Agilent) 83622A 20 GHz Synthesized Sweeper

The HP 83622A synthesized sweeper is the standard of excellence for applications requiring the high performance and accuracy of a synthesized source and the speed and versatility of a sweep oscillator. Synthesized broadband frequency coverage and precise 1 Hz frequency resolution (Option 008) are generated by indirect synthesis, enabling the HP 83622A to achieve low single-sideband phase noise performance. The HP 83622A delivers excellent harmonic performance with harmonics at least 50 dB below the carrier from 2.2 to 20 GHz. High-performance pulse modulators with >80 dB on/off ratio and rise/fall times < 10 ns (Option 006), make the HP 83622A suitable for the most demanding pulse modulation applications. In addition to its linear AM mode (100%/V), the HP 83622A offers a scan modulation mode (10 dB/V). Both modes have dc-coupled amplitude modulation capability with a 3 dB bandwidth of 100 kHz. and 99.7% (50 dB) of modulation depth, Pulse and amplitude modulation capabilities can be used independently and simultaneously. The HP 83622A also offers dc-coupled frequency modulation capabilities with rates up to 8 MHz. Specifications. Frequency Range: 2 to 20 GHz. Resolution: 1 kHz standard, 1 Hz optional. RF Output Range: +20 to -110 dBm with Opt 001. Resolution: 0.02 dB. Maximum Leveled Power: + 13 dBm. Pulse modulation On/off ratio: > 80 dB. Rise and fall times: <25 ns (< 10 ns optional). Minimum internally leveled RF pulse width: < 1us. Minimum RF pulse width: <50 ns (15 ns with Opt 006). Scan and amplitude modulation Rates (3dB BW): dc to 100 kHz. Depth: 0 to 90% (20 dB) aIld 0 to 99.7% (50 dB) above 10 Hz. Sensitivity: 100%/V and 10 dB/V. Frequency modulation Locked mode Modulation rate (3 dB BW, 500 kHz deviation): 100 kHz to 8 MHz. Maximum deviations: 8 MHz. Options. Opt 001: Add Step Attenuator. Opt 002: Internal Modulation Generator. Opt 003: Delete Front Panel Keyboard/Display. Opt 004: Rear Panel RF Output. Opt 006: Fast Pulse Modulation. Opt 008:1 Hz Frequency Resolution. Opt 700: Mate System Compatibility.



 

Standard Calibration $665.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 83622A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Averaging
Averaging is a mathematical process to reduce the variation in a measurement by summing the data points from multiple measurements and dividing by the number of points summed.

Fall Time
Fall time is the time required for the amplitude of a pulse to decrease (fall) from a specified value (usually 90 percent of the peak value exclusive of overshoot or undershoot) to another specified value (usually 10 percent of the maximum value exclusive of overshoot or undershoot).

Noise Density
Noise Density is the amount of noise within a defined bandwidth, usually normalized to 1 Hz.

Resolution Bandwidth (RBW)
Resolution Bandwidth (RBW) is the minimum bandwidth over which you can separate two signals and still see them.


Please contact us for your Keysight (Agilent) 83622A CALIBRATION and/or Keysight (Agilent) 83622A 20 GHz Synthesized Sweeper REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: