Keysight (Agilent) 83640A REPAIR and Keysight (Agilent) 83640A CALIBRATION

 
Custom-Cal has a high success rate in the repair of the Keysight (Agilent) 83640A. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 83640A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Signal Generator?
Shop for Comparable Products on our
 used Signal Generator page

 
   Keysight (Agilent) 83640A   Description / Specification:    
Keysight (Agilent) 83640A 40 GHz Synthesized Sweeper

The HP 83640A synthesized sweeper is the standard of excellence for applications requiring the high performance and accuracy of a synthesized source and the speed and versatility of a sweep oscillator. Synthesized broadband frequency coverage and precise 1 Hz frequency resolution (Option 008) are generated by indirect synthesis, enabling the HP 83640A to achieve low single-sideband phase noise performance. The HP 83640A delivers excellent harmonic performance with harmonics at least 50 dB below the carrier from 2.2 to 20 GHz. High-performance pulse modulators with >80 dB on/off ratio and rise/fall times < 10 ns (Option 006), make the HP 83640A suitable for the most demanding pulse modulation applications. In addition to its linear AM mode (100%/V), the HP 83640A offers a scan modulation mode (10 dB/V). Both modes have dc-coupled amplitude modulation capability with a 3 dB bandwidth of 100 kHz. and 99.7% (50 dB) of modulation depth, Pulse and amplitude modulation capabilities can be used independently and simultaneously. The HP 83640A also offers dc-coupled frequency modulation capabilities with rates up to 8 MHz. Specifications. Frequency Range: 10 MHz to 40 GHz. Resolution: 1 kHz standard, 1 Hz optional. RF Output Range: +20 to -110 dBm with Opt 001. Resolution: 0.02 dB. Maximum Leveled Power: + 10 dBm. Pulse modulation On/off ratio: > 80 dB. Rise and fall times: <25 ns (< 10 ns optional). Minimum internally leveled RF pulse width: < 1us. Minimum RF pulse width: <50 ns (15 ns with Opt 006). Scan and amplitude modulation Rates (3dB BW): dc to 100 kHz. Depth: 0 to 90% (20 dB) aIld 0 to 99.7% (50 dB) above 10 Hz. Sensitivity: 100%/V and 10 dB/V. Frequency modulation Locked mode Modulation rate (3 dB BW, 500 kHz deviation): 100 kHz to 8 MHz. Maximum deviations: 8 MHz. Options. Opt 001: Add Step Attenuator. Opt 002: Internal Modulation Generator. Opt 003: Delete Front Panel Keyboard/Display. Opt 004: Rear Panel RF Output. Opt 006: Fast Pulse Modulation. Opt 008:1 Hz Frequency Resolution. Opt 700: Mate System Compatibility.


Repair Services / Additional Information.


RF Connector Replacement
 Damaged or broken connector (2.4mm) on your microwave signal source or spectrum analyzer? OEM won't sell the replacement to you? Custom-Cal has the solution.  Want the connector moved from the from to rear on your signal source, this service is also the solution to undo the obsolete Model # -0041 (RF output connector moved to rear panel)
 The input and output connectors on your microwave test equipment affects more than signal fidelity. A damaged connector will destroy expensive adapters and cables.
 Whether your RF connector is worn out or was broken through mishandling or accident, Custom-Calibration Solutions will replace the OEM connector with a refurbished connector and new hard-line and bracket, as appropriate. The refurbished connector system will improve:
 Signal fidelity (flatness or frequency response)
 Input reflection (VSWR)
 Output impedance match
 Measurement repeatability
 Ease of connection
 Cable and adapter life



 

Standard Calibration $730.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 83640A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Clipping
Clipping is the limiting of a signal so that it never exceeds some threshold.

Line Regulation
Line regulation is the capability to maintain a constant output voltage level on the output channel of a power supply despite changes to the input voltage level.

Peak Envelope Power
Peak envelope power is the maximum value of the envelope power. Envelope power is measured by making the averaging time much less than 1/fm where fm is the maximum frequency component of the modulation waveform. The averaging time is therefore limited on both ends: (1) it must be small compared to the period of the highest modulation frequency, and (2) it must be large enough to be many RF cycles long.

RMS
RMS or root mean square is a statistical measure of the magnitude of a varying quantity


Please contact us for your Keysight (Agilent) 83640A REPAIR and/or Keysight (Agilent) 83640A 40 GHz Synthesized Sweeper CALIBRATION

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: