Keysight (Agilent) 83752A REPAIR and Keysight (Agilent) 83752A CALIBRATION

 
Custom-Cal has a high success rate in the repair of the Keysight (Agilent) 83752A. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 83752A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Signal Generator?
Shop for Comparable Products on our
 used Signal Generator page

 
   Keysight (Agilent) 83752A   Description / Specification:    
Keysight (Agilent) 83752A 20 GHz Synthesized Microwave Sweeper

The HP 83752A synthesized sweeper provides superior accuracy and stability while maintaining the speed of analog sources. Fully synthesized CW, stepped, and ramp sweep modes are available in broadband and narrowband operation. The synthesis capabilities are particularly useful for the characterization of narrowband devices, in which the frequency instabilities of open-loop sources become most apparent. Excellent output power flatness and accuracy can be translated to the input port of the device under test with the power flatness correction feature of these sources. This feature uses a power meter to create an array of power corrections that cnmpensate for power variations in the measurement path between the source and the test device. Swept testing of frequency translation devices can be achieved simply and economically with the HP 83572A synthesized sweeper. A traditionally difficult measurement, sweeping the RF and local oscillator (LO) input ports at a fixed offset over a wide frequency span, is easy to implement with superior frequency accuracy by positioning two synchronously tracking HP 83752A's in a two-tone configuration. With broadband frequency coverage and excellent performance, the HP 83752A synthesized sweeper is ideal stimuli for frequency translation measurements. Specifications. Frequency Range: 0.01 to 20 GHz. Maximum Leveled Power: 10 dBm. Minimum Settable Power: - 15 dBm ( - 85 dBm w/Opt 1E1). Resolution: 0.01 dB settable. Accuracy: ±1.0 dB (levels > - 10 dBm). Flatness: ±0.7 dB (levels > - 10 dBm). Power Sweep Range: 25 dB/sweep. Power Slope Range: 0 to ±2 dB/GHz, 25 dB max. Source Match (typical) : < 1.7:1 SWR. Harmonics: -30 dBc < 1.5 GHz. Bandwidth Points: 2 GHz, 3.75 GHz, 6.75 GHz, and 11 GHz. The 3.75 and 6.75 GHz synthesizer switch will disappear if sweep is <0.8 of an octave in the 2 to 11 GHz band. Options. Opt 1E1: 70 dB Step Attenuator. Opt 1E4: Rear Panel RF Output. Opt 1E5: High Stability Time Base. Opt 1ED: Type-N Connector Output.



 

Standard Calibration $760.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 83752A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Averaging
Averaging is a mathematical process to reduce the variation in a measurement by summing the data points from multiple measurements and dividing by the number of points summed.

Fall Time
Fall time is the time required for the amplitude of a pulse to decrease (fall) from a specified value (usually 90 percent of the peak value exclusive of overshoot or undershoot) to another specified value (usually 10 percent of the maximum value exclusive of overshoot or undershoot).

Noise Density
Noise Density is the amount of noise within a defined bandwidth, usually normalized to 1 Hz.

Resolution Bandwidth (RBW)
Resolution Bandwidth (RBW) is the minimum bandwidth over which you can separate two signals and still see them.


Please contact us for your Keysight (Agilent) 83752A REPAIR and/or Keysight (Agilent) 83752A 20 GHz Synthesized Microwave Sweeper CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: