Keysight (Agilent) 8413A CALIBRATION and Keysight (Agilent) 8413A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 8413A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Network Analyzer, SNA, VNA?
Shop for Comparable Products on our
 used Network Analyzer, SNA, VNA page or new Network Analyzer, SNA, VNA page

 
   Keysight (Agilent) 8413A   Description / Specification:    
Keysight (Agilent) 8413A Network Analyzer Phase/Gain Indicator

Network Analyzer Phase/Gain Indicator, displays realative amplitude and phase difference of two input signals. Amplitude: Range: ±3, ±10, and ±30 dB full scale, Accuracy: ±3% of end scale, Log Output: 50 mV per dB up to 60 dB total, bandwidth 10 kHz nominal depending on signal level, source impedance 1 kohm, accuracy ±3%. Linear Output(Rear Panel): 0 to 1 V maximum, 10 kHz bandwidth, 250 ohm source impedance. Max drift, 1 hr warmup: Log: < ±0.1 dB/°C; Linear: < ±5 mV/°C. Phase: Range: ±6, ±18, ±60 and ±180 degrees full scale, Accuracy: ±2% of end scale, Output: 10 mV per degree, 10kHz bandwidth, 1 kohm source impedance, Accuracy: ±2% of reading on auxiliary display or ±1 mV, whichever is greater, Maximum Drift: less than ±0.2 degree, Phase OffsetL ±180 degrees in 10-degree steps, accuracy: (0.2 degree + 0.3 degree per 10-degree step), not to exceed ±1.5 degrees cumulative, reference from 0 degrees. Phase Response Versus Signal Amplitude: 2 degrees max phase change for 60 dB amplitude change in test ch.



 

Standard Calibration $1,100.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 8413A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Channel Bandwidth
Channel Bandwidth is the bandwidth over which power is measured. This is usually the bandwidth in which almost all of the power of a signal is contained.

Mismatch Uncertainty
Mismatch Uncertainty is caused by re-reflections between one device (the source) and the device that follows it (the load).

Rise Time
Rise time refers to the time required for a signal to change from a specified low value to a specified high value, usually 10 and 90 percent of pulse-top amplitude (vertical display is linear power).


Please contact us for your Keysight (Agilent) 8413A CALIBRATION and/or Keysight (Agilent) 8413A Network Analyzer Phase/Gain Indicator REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: