Keysight (Agilent) 8493A CALIBRATION and Keysight (Agilent) 8493A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 8493A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another RF Attenuator?
Shop for Comparable Products on our
 used RF Attenuator page

 
   Keysight (Agilent) 8493A   Description / Specification:   Spec Sheet 
Keysight (Agilent) 8493A SMA Coaxial Fixed Attenuator

The Agilent 8493A RF attenuator is furnished with SMA type connectors. The connectors are heat treated beryllium copper for greater strength and wear. The HP 8493A attenuator achieves a flat frequency response (typically a few hundredths of a dB) and overall accuracy (typically ±2 % of value in dB at 26.5 GHz) through the use of thin-film attenuator cards. Attenuation is option specific. Specifications. Frequency range: dc to 12.4 GHz. Attenuation accuracy: 3 dB ±0.3 dB, 6 dB ±0.3 dB, 10 dB ±0.5 dB, 20 dB ±0.5 dB, 30 dB ±1.0 dB. Temperature stability: 0.0001 dB/dB/°C. Maximum input power: 2 W avg., 100 W peak. Power sensitivity: 0.001 dB/dB/W. Option 003 3 dB. Option 006 6 dB. Option 010 10 dB. Option 020 20 dB. Option 030 30 dB.



 

Standard Calibration $225.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 8493A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Available Gain
Available Gain is the ratio, at a specific frequency, of power available from the output to the power in from the source.

Frequency Span
Frequency Span specifies the range between the start and stop frequencies, also referred to as bandwidth

Peak Envelope Power
Peak envelope power is the maximum value of the envelope power. Envelope power is measured by making the averaging time much less than 1/fm where fm is the maximum frequency component of the modulation waveform. The averaging time is therefore limited on both ends: (1) it must be small compared to the period of the highest modulation frequency, and (2) it must be large enough to be many RF cycles long.


Please contact us for your Keysight (Agilent) 8493A CALIBRATION and/or Keysight (Agilent) 8493A SMA Coaxial Fixed Attenuator REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: