Keysight (Agilent) 8494B REPAIR and Keysight (Agilent) 8494B CALIBRATION

 
Custom-Cal has a high success rate in the repair of the Keysight (Agilent) 8494B. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 8494B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another RF Attenuator?
Shop for Comparable Products on our
 used RF Attenuator page

 
   Keysight (Agilent) 8494B   Description / Specification:   Spec Sheet 
Keysight (Agilent) 8494B 18 GHz 11 dB Manual Step Attenuator

The HP 8494B 18 GHz Manual Step Attenuator offers fast, precise signal level control. It features exceptional repeatability and reliability in a wide range of frequency, attenuation and connector options. Attenuation repeatability is specified to be less than 0.03 dB for 5 million cycles per section. This assures low measurement uncertainty and high user confidence when designed into automatic test systems. Electromechanical step attenuators offer low SWR, low insertion loss and high accuracy required by high-performance test and measurement equipment. Specifications. Frequency Range: DC-18 GHz. Attenuation Range: 0-11 dB, 1dB steps. Maximum SWR: 1.5 to 8 GHz, 1.6 to 12.4 GHz, 1.9 to 18 GHz. Insertion Loss at 0 dB: 0.6 dB + 0.09 dB/GHz. Attenuation Accuracy dc to 12.4 GHz: ±0.3 dB (1 to 2 dB), ±0.4 dB (3 to 4 dB), ±0.5 dB (5 to 6 dB), ±0.6 dB (7 to 10 dB), ±0.7 dB (11 dB). Attenuation Accuracy dc to 18 GHz: ±0.7 dB (1 to 5 dB), ±0.8 dB (6 to 9 dB), ±0.9 dB (10 to 11 dB). Power Rating: 1 W average, 100 W peak 10 µs max. Minimum Life: 5 million cycles per section. Option 001 N(f). Option 002 SMA(f). Option 003 APC-7.



 

Standard Calibration $295.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 8494B. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Channel Bandwidth
Channel Bandwidth is the bandwidth over which power is measured. This is usually the bandwidth in which almost all of the power of a signal is contained.

Mismatch Uncertainty
Mismatch Uncertainty is caused by re-reflections between one device (the source) and the device that follows it (the load).

Rise Time
Rise time refers to the time required for a signal to change from a specified low value to a specified high value, usually 10 and 90 percent of pulse-top amplitude (vertical display is linear power).


Please contact us for your Keysight (Agilent) 8494B REPAIR and/or Keysight (Agilent) 8494B 18 GHz 11 dB Manual Step Attenuator CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: