Keysight (Agilent) 85046A REPAIR and Keysight (Agilent) 85046A CALIBRATION

 
Custom-Cal has a high success rate in the repair of the Keysight (Agilent) 85046A. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 85046A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another S-Parameter Test Set?
Shop for Comparable Products on our
 used S-Parameter Test Set page

 
   Keysight (Agilent) 85046A   Description / Specification:    
Keysight (Agilent) 85046A 50 ohm S-parameter Test Set

The Agilent 85046A S-Parameter Test Set provides the capability to measure reflection and transmission characteristics (including S-parameters) of two port devices in either direction with a single connection. The test sets are controlled from the analyzer and include programmable step attenuators. These test sets are used with the HP 8753A/B/C or the HP 8753D Option 011 only. The HP 85046A test set provides the capability to simultaneously measure the transmission and reflection characteristics of 50 ohm devices. Specifications. Impedance: 50 Ohm. Frequency Range: 300 kHz to 6 GHz. Directivity: 300 kHz to 1.3 GHz 35 dB / 1.3 GHz to 3 GHz 30 dB / 3 GHz to 6 GHz 25 dB. Transmission Magnitude, Phase: 0.3 MHz to 2.0 MHz (±1.5 dB, ±20°) / 2.0 MHz to Fmax (±1.5 dB, ±10°). Reflection Magnitude, Phase: 0.3 MHz to 2.0 MHz (±1.5 dB, ±25°) / 2.0 MHz to Fmax (±1.5 dB, ±10°). Effective Source Match (test ports): 0.3 MHz to 2.0 MHz, 14 dB / 2.0 MHz to 1.3 GHz, 20 dB / 2.0 MHz to Fmax, 16 dB. RF connectors: Port 1, 2: 7 mm precision / All others: 50 ohm type N(f).



 

Standard Calibration $285.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 85046A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Adjacent Channel Power
Adjacent Channel Power is the power from a modulated communications channel that leaks into an adjacent channel. This leakage is usually specified as a ratio to the power in the main channel, but is sometimes an absolute power.

Fall Time
Fall time is the time required for the amplitude of a pulse to decrease (fall) from a specified value (usually 90 percent of the peak value exclusive of overshoot or undershoot) to another specified value (usually 10 percent of the maximum value exclusive of overshoot or undershoot).

Overshoot
Overshoot is the distortion that follows a major transition; the difference between the peak power point and the pulse-top amplitude computed as a percentage of the pulse-top amplitude.


Please contact us for your Keysight (Agilent) 85046A REPAIR and/or Keysight (Agilent) 85046A 50 ohm S-parameter Test Set CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: