Keysight (Agilent) 8508A REPAIR and Keysight (Agilent) 8508A CALIBRATION

The Keysight (Agilent) 8508A is currently in stock and available for purchase on our  Sales Page
It is also available for immediate rental.
Custom-Cal has a high success rate in the repair of the Keysight (Agilent) 8508A. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 8508A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another General Meter?
Shop for Comparable Products on our
 used General Meter page

 
   Keysight (Agilent) 8508A   Description / Specification:    
Keysight (Agilent) 8508A Vector Voltmeter

The HP 8508A Vector Voltmeter is a fully automatic tuned receiver that makes RF voltage and phase measurements easy. Its narrowband measuring technique gives it a dynamic range of over 90dB and a sensitivity of 10 uV to trace even the smallest signal. The HP 8508A also measures the phase difference between its two input channels with at least 0.1 degree resolution over a full + 180 to -180 degree range, so it can be used for another complete set of measurements - like electrical length, phase distortion or impedance. The standard HP 8508A is supplied with the HP 85081A Input Module, and has two high impedance probe inputs that operate from 100 kHz to 1 GHz. Its ability to store a reference and use it in later measurements means individual circuit sections can be characterized and adjusted independently. Any CW source can be used as a stimulus - even a source that is part of the device being tested, so measurements can be made under normal operating conditions. Specifications. Frequency Range: 100 kHz - 1 GHz (300 kHz - 2 GHz). Maximum Input: 2V peak ac (+ 16 dBm), ±50V dc. Options. Opt 001: Add bail handle and front protective cover. Opt 050: Replace HP 85081 A Input Module with HP 85082A Input Module. Opt 100: Delete Input Module.



 

Standard Calibration $650.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 8508A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Clipping
Clipping is the limiting of a signal so that it never exceeds some threshold.

Line Regulation
Line regulation is the capability to maintain a constant output voltage level on the output channel of a power supply despite changes to the input voltage level.

Peak Envelope Power
Peak envelope power is the maximum value of the envelope power. Envelope power is measured by making the averaging time much less than 1/fm where fm is the maximum frequency component of the modulation waveform. The averaging time is therefore limited on both ends: (1) it must be small compared to the period of the highest modulation frequency, and (2) it must be large enough to be many RF cycles long.

RMS
RMS or root mean square is a statistical measure of the magnitude of a varying quantity


Please contact us for your Keysight (Agilent) 8508A REPAIR and/or Keysight (Agilent) 8508A Vector Voltmeter CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: