Keysight (Agilent) 8563A REPAIR and Keysight (Agilent) 8563A CALIBRATION

 
Custom-Cal has a high success rate in the repair of the Keysight (Agilent) 8563A. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 8563A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another RF Spectrum Analyzer?
Shop for Comparable Products on our
 used RF Spectrum Analyzer page or new RF Spectrum Analyzer page

 
   Keysight (Agilent) 8563A   Description / Specification:    
Keysight (Agilent) 8563A 22 GHz RF Spectrum Analyzer

9 kHz to 22 GHz; 9 kHz to 26.5 GHz (opt. 026), Portable Spectrum Analyzer. Meets MIL-T- 28800C specifications for ruggedness. Manual control is simple with an easy-to-use combination of hardkeys and softkeys that minimizes the number of keystrokes required to make measurements. Other measurement features include advanced marker capability and built-in AM/FM demodulators. Hardcopies of results are easily obtained using the analyzers' direct print and plot functions or by using a computer. Scalar measurement capability is available by using the 85640A portable tracking generator. The internal preselector requires no adjustment after 30 minutes at room temperature. Frequency span Range: 0 Hz, 100 Hz x N to 19.25/ 23.75 GHz (opt 026). Frequency span Accuracy: <±5%. Resolution bandwidth ( - 3 dB). Amplitude range: + 30 dBm to displayed average noise level. Maximum dynamic range Compression to noise: 128 dB. Sweep time Range: 50 us to 60 s (zero span); 50 ms to 100 s (span >0)


Repair Services / Additional Information.


Agilent 8560 CRT Replacement
Tired of staring at an aging CRT?  Be rid of unnecessary strain on your eyes – ask Custom-Cal for a quote to retrofit the CRT with new TFT Color LCD technology!

Once we have performed the retrofit you can say good bye to any and all of the following ailments:
Dim display
Poor contrast
Fuzzy or out of focus
Hard to read mnemonics
Distortion and bowing
Problems associated with poor astigmatism

Features
Enjoy a one year warrantee on this upgrade / retrofit
NIST traceable calibration of the entire instrument at (additional cost)
Adds color mapping to the monochrome display in 3 user-selectable color schemes:
- Classic (same as the newer ESA and PSA spectrum analyzers)
- 70000 (same as the 70000 series frames)
- monochrome
Traces are unique colors for easy recognition.
Reduces unit weight by 5 lbs.
Reduces power consumption.


 

Standard Calibration $675.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 8563A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Average Power
Average power means that the energy transfer rate is to be averaged over many periods of the lowest frequency involved. For a CW signal, the lowest frequency and highest frequency are the same, so average power and power are the same. For an amplitude modulated wave, the power must be averaged over many periods of the modulation component of the signal as well.

Harmonic
A harmonic of a wave is a component frequency of the signal that is an integer multiple of the fundamental frequency, i.e. if the fundamental frequency is f, the harmonics have frequencies 2f, 3f, 4f, . . . etc.

Phase Noise
Phase noise is the frequency domain representation of rapid, short-term, random fluctuations in the phase of a waveform, caused by time domain instabilities. Phase noise (L(f)) is typically expressed in units of dBc/Hz, representing the noise power relative to the carrier contained in a 1 Hz bandwidth centered at a certain offsets from the carrier.


Please contact us for your Keysight (Agilent) 8563A REPAIR and/or Keysight (Agilent) 8563A 22 GHz RF Spectrum Analyzer CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*