Keysight (Agilent) 8569B CALIBRATION and Keysight (Agilent) 8569B REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 8569B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another RF Spectrum Analyzer?
Shop for Comparable Products on our
 used RF Spectrum Analyzer page or new RF Spectrum Analyzer page

 
   Keysight (Agilent) 8569B   Description / Specification:    
Keysight (Agilent) 8569B 22 GHz Spectrum Analyzer

10 MHz to 22 GHz, 14.5 to 40 GHz with Opt. E30, external mixing to 115 GHz, Simplified three knob operation, Internal preselection, 1.7 to 22 GHz, Wide resolution range, 100 Hz to 3 MHz, Digital display of traces, control settings, Microwave Spectrum Analyzer. Amplitude Range total power: +30 dBm, +137 dBµV (1 watt). Gain compression: <1 dB for -7 dBm signal, 0 dB input atten. Tuning Accuracy 10 MHz to 115 GHz: ± (5 MHz or 0.2 % of center frequency, whichever is greater, +20% of frequency Span/Div.)



 

Standard Calibration $675.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 8569B. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Channel Bandwidth
Channel Bandwidth is the bandwidth over which power is measured. This is usually the bandwidth in which almost all of the power of a signal is contained.

Mismatch Uncertainty
Mismatch Uncertainty is caused by re-reflections between one device (the source) and the device that follows it (the load).

Rise Time
Rise time refers to the time required for a signal to change from a specified low value to a specified high value, usually 10 and 90 percent of pulse-top amplitude (vertical display is linear power).


Please contact us for your Keysight (Agilent) 8569B CALIBRATION and/or Keysight (Agilent) 8569B 22 GHz Spectrum Analyzer REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: