Keysight (Agilent) 8590D CALIBRATION and Keysight (Agilent) 8590D REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 8590D Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another RF Spectrum Analyzer?
Shop for Comparable Products on our
 used RF Spectrum Analyzer page or new RF Spectrum Analyzer page

 
   Keysight (Agilent) 8590D   Description / Specification:    
Keysight (Agilent) 8590D 1.8 GHz RF Spectrum Analyzer

9 kHz to 1.8 GHZ Spectrum Analyzer; 50 Ohm Input Impedance, 9 kHz Min Frequency, 0.0000000002 % Frequency Accuracy, 10 kHz Min Span, 1.8 GHz Max Span, 20 ms Min Sweep Time, 100 s Max Sweep Time, 1 kHz Min Resolution Bandwidth, 3 MHz Max Resolution Bandwidth, 1/3/10 Resolution Bandwidth Steps, 30 Hz Min Video Bandwidth, 1 MHz Max Video Bandwidth, -95 dBc/Hz Min Single-Side-Band Noise, 1 dBm Max Safe AC Input, 25 V Max DC Input, -115 dBm Min Displayed Avg Noise, -113 dBm Max displayed Avg Noise, 3 % Maximum Amplitude Uncertainty, HPIB and RS232 Ports to Peripheral Devices



 

Standard Calibration $780.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 8590D. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Adjacent Channel Power
Adjacent Channel Power is the power from a modulated communications channel that leaks into an adjacent channel. This leakage is usually specified as a ratio to the power in the main channel, but is sometimes an absolute power.

Fall Time
Fall time is the time required for the amplitude of a pulse to decrease (fall) from a specified value (usually 90 percent of the peak value exclusive of overshoot or undershoot) to another specified value (usually 10 percent of the maximum value exclusive of overshoot or undershoot).

Overshoot
Overshoot is the distortion that follows a major transition; the difference between the peak power point and the pulse-top amplitude computed as a percentage of the pulse-top amplitude.


Please contact us for your Keysight (Agilent) 8590D CALIBRATION and/or Keysight (Agilent) 8590D 1.8 GHz RF Spectrum Analyzer REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: