Keysight (Agilent) 8595E REPAIR and Keysight (Agilent) 8595E CALIBRATION

The Keysight (Agilent) 8595E is currently in stock and available for purchase on our  Sales Page
It is also available for immediate rental.
Custom-Cal has a high success rate in the repair of the Keysight (Agilent) 8595E. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 8595E Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another RF Spectrum Analyzer?
Shop for Comparable Products on our
 used RF Spectrum Analyzer page or new RF Spectrum Analyzer page

 
   Keysight (Agilent) 8595E   Description / Specification:    
Keysight (Agilent) 8595E 6.5 GHz RF Spectrum Analyzer

The Agilent 8595E 6.5 GHz portable spectrum analyzer brings powerful, comprehensive measurement capabilities to RF, microwave and digital applications. Performance specifications include low phase noise of -105 dBc at 30 kHz offset and frequency-synthesized accuracy of 2.1 kHz at 1 GHz, which can be improved to 210 Hz with an optional precision frequency reference. Second- and third-order dynamic ranges are 77 and 90 dB, respectively. Calibrated amplitude range is +30 to -130 dBm with Option 130, and calibrated onscreen display range is 70 dB. Narrow resolution bandwidths of 30, 100, 200 EMI and 300 Hz are available on an optional circuit card, which can be added to these analyzers at any time. Specifications. Frequency range: 9 kHz to 6.5 GHz. Frequency accuracy: ± 210 Hz (CF = 1 GHz). Frequency Span Range: 0 Hz (zero span); 10 kHz to 6.5 GHz: 1 kHz min (Opt 130). Frequency Span Resolution: Four digits or 20 Hz x N. whichever is greater. Frequency Span Accuracy Span =10 MHz x N: ± 2% of span. Frequency Span Accuracy Span >10 MHz x N: ± 3% of span. Sweep Time Range: Span = 0 Hz or > 10 kHz: 20 ms to 100 s. Resolution bandwidth range: 30 Hz to 3 MHz. Video bandwidth range: 30 Hz to 1 MHz in 1, 3 sequence (1 Hz to 1 MHz with Opt 130). Amplitude Range: Displayed average noise level to +30 dBm. Average noise level (narrowest RBW): -125 dBm. Optimum dynamic range 2nd/3rd order: 77 dB / 86 dB. Amplitude accuracy: ± 2.2dB. Data Storage (nominal)Internal: 50 traces; 8 states. Instrument Options: 004, Precision Frequency Reference. 009, LO and Sweep + Tune. 010, 50 ? Built-in Tracking Generator, 9 kHz to 2.9 GHz. 012, Source for DECT Receiver Test. 041, HP-IB and Parallel Printer Interfaces. 043, RS-232 and Parallel Printer Interfaces. 050, Improved Amplitude Accuracy (NADCTDMA bands). 051, Improved Amplitude Accuracy for PDC Bands. 052, Improved Amplitude Accuracy for PHS Bands. 053, Improved Amplitude Accuracy for CDMA Bands. 101, Fast Time Domain Sweeps and Analog + Display. 102, AM/FM Demodulator and TV Sync Trigger(TV Sync requires Opt 101). 103, Quasi-Peak Detector/AM-FM Demodulator. 105, Time-gated Spectrum Analysis. 107, TV Receiver Video Tester. 110, CT2 Demodulator. 111, Group Delay and Amplitude Flatness. 112, DECT Demodulator. 119, Noise Figure. 130, Narrow Resolution Bandwidths (30 to 300 Hz and 200 Hz EMI). 140, Narrow Bandwidths and Precision Frequency. 151, DSP, FAST ADC, and Digital Demodulator. 160, PDC, PHS, NADC, and CDMA Firmware for Opt 151. 163, GMS/DCS1800 Firmware for Option 151. 180, TV Picture NTSC/PAL/SECAM. 301, TV Sync Trigger, Fast Time Domain Sweeps, AM/FM Demodulator, Analog + Display. 711, 50/75? Matching Pad/100 Vdc Block. Measurement Personalities: 11770A, Link Measurement Personality. 85700A, Blank 32-KB Memory Card. 85702A, Blank 128-KB Memory Card. 85712D, EMC Auto-Measurement Personality. 85713A, Digital Radio Measurement Personality. 85714A, Scalar Measurement Personality. 85715B, GSM Measurement Personality. 85717A, CT2-CAI Measurement Personality. 85718B, NADC-TDMA Measurement Personality. 85719A, Noise Figure Measurement Personality. 85720C, PDC Measurement Personality. 85721A, Cable TV Measurements and System Monitor Personality. 85722B, DCS1800 Measurement Personality. 85723A, Option H01 DECT Measurement Personality. 85724A, Broadcast Measurement Personality. 11982A, Opt 001 Lightwave Converter Personality. 85725B, CDMA Measurement Personality. 85726B, PHS Measurement Personality.



 

Standard Calibration $675.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 8595E. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Channel Bandwidth
Channel Bandwidth is the bandwidth over which power is measured. This is usually the bandwidth in which almost all of the power of a signal is contained.

Mismatch Uncertainty
Mismatch Uncertainty is caused by re-reflections between one device (the source) and the device that follows it (the load).

Rise Time
Rise time refers to the time required for a signal to change from a specified low value to a specified high value, usually 10 and 90 percent of pulse-top amplitude (vertical display is linear power).


Please contact us for your Keysight (Agilent) 8595E REPAIR and/or Keysight (Agilent) 8595E 6.5 GHz RF Spectrum Analyzer CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: