Keysight (Agilent) 86100B REPAIR and Keysight (Agilent) 86100B CALIBRATION

 
Custom-Cal has a high success rate in the repair of the Keysight (Agilent) 86100B. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 86100B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Communication Analyzer?
Shop for Comparable Products on our
 used Communication Analyzer page or new Communication Analyzer page

 
   Keysight (Agilent) 86100B   Description / Specification:    
Keysight (Agilent) 86100B Infinium DCA Wide-Bandwidth Oscilloscope

The 86100B Infiniium DCA can be viewed as three high-performance instruments in one. It’s a general-purpose wide-bandwidth sampling oscilloscope, a digital communications analyzer and a time domain reflectometer. Standard Measurements; Oscilloscope Mode (Time): Rise Time, Fall Time, Jitter RMS, Jitter p-p, Period, Frequency, + Pulse Width, - Pulse Width, Duty Cycle, Delta Time, [Tmax, Tmin, Tedge—remote commands only]. Oscilloscope Mode (Amplitude): Overshoot, Average Power, V amptd, V p-p, V rms, V top, V base, V max, V min, V avg. Eye/Mask Mode (NRZ Eye Measurements): Extinction Ratio, Jitter RMS, Jitter p-p, Average Power, Crossing Percentage, Rise Time, Fall Time, One Level, Zero Level, Eye Height, Eye Width, Signal to Noise (Q-Factor), Duty Cycle Distortion, Bit Rate, Eye Amplitude. Eye/Mask Mode (RZ Eye Measurements): Extinction Ratio, Jitter RMS, Jitter p-p, Average Power, Rise Time, Fall Time, One Level, Zero Level, Eye Height, Eye Amplitude, Opening Factor, Eye Width, Pulse Width, Signal to Noise (Q-Factor), Duty Cycle, Bit Rate, Contrast Ratio. Mask Test: Open Mask, Start Mask Test, Exit Mask Test, Filter, Mask Test Margins, Mask Test Scaling, Create NRZ Mask. TDR/TDT Mode (requires TDR module): Quick TDR, TDR/TDT Setup, Normalize, Response, Rise Time, Fall Time, delta Time. Time Base Scale Factor: Min 2 ps/div (with 86107A: 500 fs/div), Max 1 s/div. Time Base Delay: Min >=24 ns (Standard), 28 ns (Option 001). Number of Channels: 4 (simultaneous acquisition). Vertical Resolution: 12 bit A/D converter (up to 15 bits with averaging). Trigger Sensitivity: 200 m Vpp (sinusoidal input or 200 ps minimum pulse width). Trigger Bandwidth (Module dependent): 2.4 to 43 GHz.



 

Standard Calibration $595.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 86100B. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Communication Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Extinction Ratio
Extinction ratio is the ratio of two optical power levels, of a digital signal generated by an optical source, where P1 is the optical power level generated when the light source is "on," and P0 is the power level generated when the light source is "off." The extinction ratio may be expressed as a fraction, in dB, or as a percentage. Extinction ratio = P1/P0

Receiver
A receiver is a detector and electronic circuitry to change optical signals into electrical signals.

Telecom Bands
Optical fiber communications typically operate in a wavelength region corresponding to one of the following Bands. O Band (original): 1260–1360 nm. E Band (extended): 1360–1460 nm. S Band (short wavelengths): 1460–1530 nm. C Band (conventional): 1530–1565 nm. L Band (long wavelengths): 1565–1625 nm. U Band (ultralong wavelengths): 1625–1675 nm


Please contact us for your Keysight (Agilent) 86100B REPAIR and/or Keysight (Agilent) 86100B Infinium DCA Wide-Bandwidth Oscilloscope CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: