Keysight (Agilent) 86143A REPAIR and Keysight (Agilent) 86143A CALIBRATION

 
Custom-Cal has a high success rate in the repair of the Keysight (Agilent) 86143A. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 86143A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Optical Spectrum Analyzer, OSA?
Shop for Comparable Products on our
 used Optical Spectrum Analyzer, OSA page or new Optical Spectrum Analyzer, OSA page

As an alternative New Ridge Technologies offers the NRT-8000, the world’s Smallest Optical Spectrum Analyzer with built in “live wavelength calibration” for C-Band applications.  More
   Keysight (Agilent) 86143A   Description / Specification:    
Keysight (Agilent) 86143A 600 to 1700nm Standard Performance Optical Spectrum Analyzer

600 nm to 1700 nm, Standard performance portable Optical Spectrum Analyzer, 9/125 um optical input. Wavelength Reproducibility (1 min): ±0.003 nm. Wavelength Span Range: 0.2 nm to full range and zero span. Wavelength Absolute Accuracy: ±0.5 nm. Wavelength Span Linearity: 1525 nm - 1570 nm, ±0.02 nm. Wavelength Span Linearity: ±0.05 nm, for spans <40nm. Maximum Sensitivity (1250-1610 nm): –90 dBm. Maximum Sweep Rate: 40 nm/50 ms. Max Measurement Power: +15 dBm per channel (+12 dBm per channel, 1000–1525 nm), +30 dBm total. Dynamic Range In 0.1 nm resolution 1250–1610 nm (chop mode on) ±0.5 nm, ±1 nm, ±5 nm: 70 dB. Resolution Bandwidth: 0.07 nm, 0.1 nm, 0.2 nm, 0.5 nm, 1 nm, 2 nm, 5 nm, 10 nm



Looking for a replacement? Try the  DEVISER AE8600

Standard Calibration $540.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 86143A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Optical Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBm
Optical power referenced to 1 millimatt

Multimode Fiber
Multimode Fiber has a large core (almost always 62.5 microns - a micron is one one millionth of a meter - but sometimes 50 microns) and is used with LED sources at wavelengths of 850 and 1300 nm for short distance, lower speed networks like LANs. Both multimode and singlemode fiber have an outside diameter of 125 microns - about 5 thousandths of an inch - just slightly larger than a human hair.

Power Repeatability
Power Repeatability is the random uncertainty in reproducing the power level after changing and re-setting the power level. The power repeatability is ± half the span (in dB) between the highest and lowest actual power. Note: - The long-term power repeatability can be obtained by taken the power repeatability and power stability into account.

Refractive Index
The refractive index or index of refraction of a substance is a measure of the speed of light in that substance. It is expressed as a ratio of the speed of light in vacuum relative to that in the considered medium. The velocity at which light travels in vacuum is a physical constant, and the fastest speed at which energy or information can be transferred. However, light travels slower through any given material, or medium, that is not vacuum.

Total insertion loss
A measure of the loss of light within an optical component


Please contact us for your Keysight (Agilent) 86143A REPAIR and/or Keysight (Agilent) 86143A 600 to 1700nm Standard Performance Optical Spectrum Analyzer CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: