Keysight (Agilent) 86144B CALIBRATION and Keysight (Agilent) 86144B REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 86144B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Optical Spectrum Analyzer, OSA?
Shop for Comparable Products on our
 used Optical Spectrum Analyzer, OSA page or new Optical Spectrum Analyzer, OSA page

As an alternative New Ridge Technologies offers the NRT-8000, the world’s Smallest Optical Spectrum Analyzer with built in “live wavelength calibration” for C-Band applications.  More
   Keysight (Agilent) 86144B   Description / Specification:   Spec Sheet 
Keysight (Agilent) 86144B 600 to 1700nm Standard Performance Optical Spectrum Analyzer

600 nm to 1700 nm, Standard performance portable Optical Spectrum Analyzer, 9/125 um optical input, with Filter Mode. Wavelength Reproducibility <= 1 min: ±0.002 nm. Wavelength Span Range: 0.2 nm to full range and zero span. Wavelength Absolute Accuracy: ±0.5 nm. Wavelength Span Linearity: 1525 nm - 1570 nm, ±0.01 nm. Wavelength Span Linearity: for spans <40 nm, ±0.02 nm. Maximum Sensitivity (1250-1610 nm): –90 dBm. Maximum Sweep Rate: 40 nm/56.3 ms. Max Measurement Power: +15 dBm per channel, +30 dBm total. Dynamic Range: 70 dB. Resolution Bandwidth: 0.06 nm, 0.07 nm, 0.1 nm, 0.14 nm, 0.2 nm, 0.33 nm, 0.5 nm, 1 nm, 2 nm, 5 nm, 10 nm.



Looking for a replacement? Try the  DEVISER AE8600

Standard Calibration $540.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 86144B. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Optical Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Amplified Spontaneous Emission Source (ASE)
ASE, a process where spontaneously emitted radiation (luminescence) is amplified. In lasers and particularly in high-gain erbium-doped amplifiers, amplified spontaneous emission is usually an unwanted effect. It tends to limit the gain achievable in a single stage of a fiber optic amplifier to the order of 40–50 dB.

Dynamic Range
In a transmission system, the ratio of the overload level to the noise level of the system, usually expressed in dB. Ratio of the highest to lowest detectable signal of a system, expressed in dB.

Optical Power
Optical Power is usually measured in "dBm", or decibels referenced to one miliwatt of power. while loss is a relative reading, optical power is an absolute measurement, referenced to standards. You measure absolute power to test transmitters or receivers and relative power to test loss.

Relative Wavelength Accuracy
When randomly changing the wavelength and measuring the differences between the actual and displayed wavelengths, the relative wavelength accuracy is ± half the span between the maximum and the minimum value of all differences.

Wavelength
Wavelength is a term for the color of light, usually expressed in nanometers (nm) or microns (m). In Fiber Optics the wavelenghts mostly used are in the infrared region where the light is invisible to the human eye.


Please contact us for your Keysight (Agilent) 86144B CALIBRATION and/or Keysight (Agilent) 86144B 600 to 1700nm Standard Performance Optical Spectrum Analyzer REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: