Custom-Cal has a high success rate in the repair of the Keysight (Agilent) 8642A. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 8642A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Signal Generator?
Shop for Comparable Products on our
 used Signal Generator page

 
   Keysight (Agilent) 8642A   Description / Specification:    
Keysight (Agilent) 8642A 1057.5 MHz Synthesized Signal Generator

The HP 8642A synthesized signal generator is a high performance programmable signal generator intended for the most demanding out-of-channel RF receiver measurements and other stringent RF applications. It provides state-of-the-art SSB phase noise at 20 kHz offsets of -134 dBc/ Hz at 1 GHz. Nonharmonic spurious are held to below -100 dBc on the HP 8642A up to 1 GHz and to below -94 dBc above 1 GHz. This generator allows receiver spurious rejection tests to be fully automated with the utmost confidence in test results. In addition to a high-reliability attenuator, absolute output level accuracy is ±1 dB down to -127 dBm (0.1 uV) . The HP 8642A offers AM, FM, M and pulse modulation across their full frequency ranges. A low distortion internal modulation oscillator can be used to modulate the HP 8642A up to 100 kHz rates. The internal audio oscillator can also be used as a stand-alone audio source with variable rates and levels. Frequency Range: 100 kHz to 1057.5 MHz. Resolution: 1 Hz, 0.1 Hz with special function. Output Level range: from maximum available to -140 dBm (0.023 uV). Resolution: 0.1 dB. Absolute accuracy: ±1 dB, output level >= -127 dBm. Flatness: <= ±0.75 dB, +10 dBm output level. Opt 001 High stability time base. Opt 002 Input/output connectors on rear panel only.



 

Standard Calibration $650.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 8642A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBc
dBc (decibels relative to the carrier) is the power ratio of a signal to a carrier signal, expressed in decibels. If the dBc figure is positive, then the relative signal strength is greater than the carrier signal strength. If the dBc figure is negative, then the relative signal strength is less than carrier signal strength.

Load Regulation
Load regulation is the capability to maintain a constant voltage (or current) level on the output channel of a power supply despite changes in the supply's load (such as a change in resistance value connected across the supply output).

Power Linearity
When changing the power level and measuring the differences (in dB) between actual and displayed power levels, the power linearity is ± half the span (in dB) between the maximum and the minimum value of all differences.

Settling Time
Settling time of an output device is the time elapsed from the application of an ideal instantaneous step input to the time at which the amplifier output has entered and remained within a specified error band, usually symmetrical about the final value.


Please contact us for your Keysight (Agilent) 8642A REPAIR and/or Keysight (Agilent) 8642A 1057.5 MHz Synthesized Signal Generator CALIBRATION

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: