Custom-Cal has a high success rate in the repair of the Keysight (Agilent) 8719C. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 8719C Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Network Analyzer, SNA, VNA?
Shop for Comparable Products on our
 used Network Analyzer, SNA, VNA page or new Network Analyzer, SNA, VNA page

 
   Keysight (Agilent) 8719C   Description / Specification:    
Keysight (Agilent) 8719C 13.5 GHz Vector Network Analyzer

The HP 8719C 50 MHz to 13.5 GHz, Microwave Network Analyzer, Includes a fast-sweeping synthesized source with optional 1 Hz frequency resolution, integrated switching test set measures all four S-parameters with a single connection, tuned reciever, and large color display in a single package. Vector accuracy enhancement, and optional time domain capability computes and displays response versus time or distance, optional solid state switch allows simultaneous measurement of forward and reverse parameters and continuous update for all four s-parameters as required for two-part error correction. Productivity is enhanced with pass/fail testing, direct printer/plotter output of results, advanced marker functions, and save/recall of test configs. Two independent display channels for simultaneous measurement of reflection and transmission characteristics. Specifications. Minimum frequency: 50 MHz. Maximum frequency: 13.5 GHz. Frequency resolution (std): 100 kHz. Frequency accuracy: 10 ppm. Maximum power: +10 dBm. Minimum power: -65 dBm. Power resolution: 0.1 dB. Power flatness: ±2.0 dB. Power sweep range: 20 dB. Receiver sensitivity (> 2 GHz): -93 dBm. System dynamic range (> 2 GHz): 103 dB. Measurement Rate (typical, 201-point sweep): <2 ms/point (1-port) to < 5 ms/point (full 2-port). Options: Opt 001 1 Hz Frequency Resolution. Opt 010 Time Domain Capability. Opt 011 Direct-Access Receiver Configuration. Opt 802 Add HP 9122C Dual Disk Drive. Opt 003 High Forward (S21) Dynamic Range.



 

Standard Calibration $675.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 8719C. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Clipping
Clipping is the limiting of a signal so that it never exceeds some threshold.

Modulation
Modulation is the coding of information onto the carrier frequency. This includes amplitude, frequency, or phase modulation techniques.

Sensitivity
Sensitivity is the smallest signal that can reliably detected. Sensitivity specifies the strength of the smallest signal at the input that causes the output signal power to be M times the output noise power where M must be specified. M=1 is very popular


Please contact us for your Keysight (Agilent) 8719C REPAIR and/or Keysight (Agilent) 8719C 13.5 GHz Vector Network Analyzer CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: