Keysight (Agilent) 8720B REPAIR and Keysight (Agilent) 8720B CALIBRATION

 
Custom-Cal has a high success rate in the repair of the Keysight (Agilent) 8720B. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 8720B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Network Analyzer, SNA, VNA?
Shop for Comparable Products on our
 used Network Analyzer, SNA, VNA page or new Network Analyzer, SNA, VNA page

 
   Keysight (Agilent) 8720B   Description / Specification:    
Keysight (Agilent) 8720B Microwave Network Analyzer

The HP 8720B microwave network analyzers characterize microwave components and networks to 20 GHz. These vector network analyzers include a fast-sweeping synthesized source, switching s-parameter test set, and large, full color display. The integral source is fully synthesized, even while sweeping, and it provides stability and accuracy within 10 ppm (typical). Measurement update times are typically about 1 ms per point. Frequency resolution is 100 kHz standard; option 001 provides 1 Hz resolution for narrow-band or long devices. It has tuned receivers and variable-bandwidth IF filters, and provides over 85 dB of dynamic range. Option 003 boosts the forward dynamic range to 95 dB; solutions to 100 dB are available. The built-in test set measures all four s-parameters (both forward and reverse) with a single connection. A step attenuator controls incident power level from -10 to -65 dBm in 5 dB steps, and two internal tees provide bias to active devices through the test ports. Two independent channels can display reflection and transmission characteristics at the same time. The receiver detects both magnitude and phase, and presents results in a variety of useful formats, including group delay, deviation from linear phase, complex impedance, or SWR, on rectangular, polar, or Smith charts. Frequency range: 130 MHz to 20 GHz, Up to 95 dB dynamic range, Directivity of 40 dB, source match of 30 dB, load match 35 dB from 0.13 to 2 GHz and 30 dB from 2 to 20 GHz, Resolution of 100 kHz, Impedance of 50 ohms, Switch type is mechanical, maximum input level of +20 dBm.



 

Standard Calibration $675.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 8720B. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Average Power
Average power means that the energy transfer rate is to be averaged over many periods of the lowest frequency involved. For a CW signal, the lowest frequency and highest frequency are the same, so average power and power are the same. For an amplitude modulated wave, the power must be averaged over many periods of the modulation component of the signal as well.

Harmonic
A harmonic of a wave is a component frequency of the signal that is an integer multiple of the fundamental frequency, i.e. if the fundamental frequency is f, the harmonics have frequencies 2f, 3f, 4f, . . . etc.

Phase Noise
Phase noise is the frequency domain representation of rapid, short-term, random fluctuations in the phase of a waveform, caused by time domain instabilities. Phase noise (L(f)) is typically expressed in units of dBc/Hz, representing the noise power relative to the carrier contained in a 1 Hz bandwidth centered at a certain offsets from the carrier.


Please contact us for your Keysight (Agilent) 8720B REPAIR and/or Keysight (Agilent) 8720B Microwave Network Analyzer CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: