Custom-Cal has a high success rate in the repair of the Keysight (Agilent) 8720D. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 8720D Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Network Analyzer, SNA, VNA?
Shop for Comparable Products on our
 used Network Analyzer, SNA, VNA page or new Network Analyzer, SNA, VNA page

 
   Keysight (Agilent) 8720D   Description / Specification:    
Keysight (Agilent) 8720D Vector Network Analyzer

The HP 8720D vector network analyzers offer builtin source, receiver, and solid-state switching S-parameter test set covering frequencies from 50 MHz to 20 GHz. They have a fast source that is fully synthesized, in both swept or stepped modes, with stability and accuracy within 10 ppm (typical). Frequency resolution is 1 Hz standard for accurate measurements of narrowband or long-delay devices. The tuned receivers with variable bandwidth IF filters provide up to 105 dB of dynamic range. A solid-state switching test set provides continuous updating of all four S-parameters as required for two-port error correction. Frequency Range: 50 MHz to 20 GHz. Frequency Resolution: 1 Hz. Frequency Accuracy: 10 ppm. Maximum Source Power: +5 dBm (std), +10 dBm (Option 007). Minimum Source Power: -70 dBm (std), -65 dBm (Option 007). Power Resolution: 0.01 dB. Power Flatness: ± 1.5 dB. Power Sweep Range: 20 dB. System Dynamic Range (>2 GHz): 100 dB, 105 dB (Option 007). Test Port Connector 3.5 mm. Options: 007, Mechanical Transfer Switch. 010, Time Domain Capability. 012, Direct Sampler Access. 085, High-Power Test Set. 089, Frequency Offset Mode. 1D5, High-Stability Frequency Reference. 400, Four-Sampler Test Set.



 

Standard Calibration $675.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 8720D. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Available Gain
Available Gain is the ratio, at a specific frequency, of power available from the output to the power in from the source.

Frequency Span
Frequency Span specifies the range between the start and stop frequencies, also referred to as bandwidth

Peak Envelope Power
Peak envelope power is the maximum value of the envelope power. Envelope power is measured by making the averaging time much less than 1/fm where fm is the maximum frequency component of the modulation waveform. The averaging time is therefore limited on both ends: (1) it must be small compared to the period of the highest modulation frequency, and (2) it must be large enough to be many RF cycles long.


Please contact us for your Keysight (Agilent) 8720D REPAIR and/or Keysight (Agilent) 8720D Vector Network Analyzer CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: