Keysight (Agilent) 8722ES REPAIR and Keysight (Agilent) 8722ES CALIBRATION

 
Custom-Cal has a high success rate in the repair of the Keysight (Agilent) 8722ES. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 8722ES Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Network Analyzer, SNA, VNA?
Shop for Comparable Products on our
 used Network Analyzer, SNA, VNA page or new Network Analyzer, SNA, VNA page

 
   Keysight (Agilent) 8722ES   Description / Specification:    
Keysight (Agilent) 8722ES S-Parameter Vector Network Analyzer

Agilent 8722ES, 50 MHz to 40 GHz, S-Parameter vector network analyzer. Frequency Accuracy (at 23° C ±3° C): ±10 ppm. Frequency Stability 0° to 55° C: ±7.5 ppm, Option 1D5 ±0.05 ppm. Frequency Resolution: 1 Hz. System Maximum input level: 10 dBm. System Trace noise, Magnitude (RMS of peak-to-peak value): 0.05 to 13.5 GHz <0.03 dB, 13.5 to 20 GHz <0.04 dB, 20 to 40 GHz <0.15 dB. System Trace noise, Phase (RMS of peak-to-peak value): 0.05 to 13.5 GHz <0.3°, 13.5 to 20 GHz <0.4°, 20 to 40 GHz <1.5°. Spectral purity, Harmonics at maximum output level: <–15 dBc. Spectral purity, Phase noise: to 60 kHz from carrier at 2 GHz <–55 dBc, to 60 kHz from carrier at 20 GHz <–35 dBc. Spectral purity, Nonharmonic spurious signals: at 100 kHz offset <–40 dBc, at 200 kHz offset <–45 dBc, at >200 kHz offset <–65 dBc. Power range: 0.05 to 20 GHz 70 dB, 20 to 40 GHz 65 dB. Resolution Level accuracy (at 5 dB below maximum output power): ±3 dB. Power sweep range: 0.05 to 20 GHz, 15 dB; 20 to 40 GHz, 10 dB (0.05 to 20 GHz, 25 dB; 20 to 40 GHz 20 dB typical). Power linearity: –5 dB from reference, 0.05 to 20 GHz ±0.35(20 to 40 GHz ±0.60); +5 dB from reference, 0.05 to 20 GHz ±0.35 (20 to 40 GHz N/A); –10 dB from reference, ±0.60; +10 dB from reference, NA. System Dynamic range (standard, Options 085, 400): 0.05 to 0.84 GHz, 67 dB; 0.84 to 8 GHz, 98 dB; 8 to 20 GHz, 91 dB; 20 to 40 GHz, 80 dB. Measured number of points per sweep: Linear frequency: choose 3, 11, 21, 51, 101, 201, 401, 801, or 1601 points. GPIB interface



 

Standard Calibration $810.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 8722ES. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Dynamic range
Dynamic range the ratio of a specified maximum level of a parameter, such as power, current, voltage or frequency, to the minimum detectable value of that parameter.

Noise Floor
Noise floor is the measure of the signal created from the sum of all the noise sources and unwanted signals within a measurement system.

White Noise
White noise is noise whose power spectral density (watts/hertz) is constant for the frequency range of interest.


Please contact us for your Keysight (Agilent) 8722ES REPAIR and/or Keysight (Agilent) 8722ES S-Parameter Vector Network Analyzer CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: