Keysight (Agilent) 8752C REPAIR and Keysight (Agilent) 8752C CALIBRATION

 
Custom-Cal has a high success rate in the repair of the Keysight (Agilent) 8752C. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 8752C Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Network Analyzer, SNA, VNA?
Shop for Comparable Products on our
 used Network Analyzer, SNA, VNA page or new Network Analyzer, SNA, VNA page

 
   Keysight (Agilent) 8752C   Description / Specification:    
Keysight (Agilent) 8752C RF Network Analyzer

The HP 8752C RF network analyzer provides simple and complete vector network measurements in a compact, fully-integrated RF network analyzer. The integrated synthesized source provides measurement port power level of +5 to -20 dBm with linear, log, list, power, and CW sweep types. A new built-in step attenuator (Option 004) gives an improved power range of +10 to -85 dBm for testing power sensitive devices such as amplifiers. The sensitive tuned receivers provide up to 110 dB of dynamic range. Source Frequency Range: 300 kHz to 1.3 GHz (std.); 300 kHz to 3 GHz (Option 003); 300 kHz to 6 GHz (Option 006). Source Frequency Resolution: 1 Hz. Accuracy: ±10 ppm at 25° ± 5° C. Output Power Range: -20 to +5 dBm (std), -85 to +10 dBm (Option 004), -85 to +8 dBm (Option 004 and 075). Output Resolution: 0.05 dB. Output Level Accuracy: ±1 dB. Output Level Linearity relative to -5 dBm output level: (-20 to -15 dBm) ±0.5 dB; (-15 to 0 dBm) ±0.2 dB; (0 to +5 dBm) ±0.5 dB. Receiver Frequency Range: 300 kHz to 1.3 GHz (std.), 300 kHz to 3 GHz (Option 003), 300 kHz to 6 GHz (Option 006). Receiver Reflection: -75 dBm (3 kHz IF BW), -85 dBm (10 Hz IF BW). Receiver Transmission: -90 dBm (3 kHz IF BW), -110 dBm (10 Hz IF BW) [300 kHz to 3 GHz]; -85 dBm (3 kHz IF BW), -105 dBm (10 Hz IF BW) [3 to 6 GHz]. Group Delay Range: 1/(2 x minimum aperture). Aperture: Frequency span/(no. of points -1), up to 20% of frequency span. Accuracy (in seconds): (phase accuracy (in degrees)/ (360 x aperture in Hz). Options: 003, 3 GHz Frequency Extension. 004, Step Attenuator. 006, 6 GHz Frequency Extension. 010, Time-Domain Capability. 075, 75 ohm Impedance. 802, Add Dual Disk Drive and HP-IB Cable.



 

Standard Calibration $780.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 8752C. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Adjacent Channel Power
Adjacent Channel Power is the power from a modulated communications channel that leaks into an adjacent channel. This leakage is usually specified as a ratio to the power in the main channel, but is sometimes an absolute power.

Fall Time
Fall time is the time required for the amplitude of a pulse to decrease (fall) from a specified value (usually 90 percent of the peak value exclusive of overshoot or undershoot) to another specified value (usually 10 percent of the maximum value exclusive of overshoot or undershoot).

Overshoot
Overshoot is the distortion that follows a major transition; the difference between the peak power point and the pulse-top amplitude computed as a percentage of the pulse-top amplitude.


Please contact us for your Keysight (Agilent) 8752C REPAIR and/or Keysight (Agilent) 8752C RF Network Analyzer CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: