Keysight (Agilent) 8753ES REPAIR and Keysight (Agilent) 8753ES CALIBRATION

The Keysight (Agilent) 8753ES is currently in stock and available for purchase on our  Sales Page
It is also available for immediate rental.
Custom-Cal has a high success rate in the repair of the Keysight (Agilent) 8753ES. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 8753ES Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Network Analyzer, SNA, VNA?
Shop for Comparable Products on our
 used Network Analyzer, SNA, VNA page or new Network Analyzer, SNA, VNA page

 
   Keysight (Agilent) 8753ES   Description / Specification:   Spec Sheet 
Keysight (Agilent) 8753ES S-parameter Network Analyzer

Agilent 8753ES S-parameter vector network analyzer Specifications. Frequency Range: 30 kHz to 3 GHz; (Option 006) 30 kHz to 6 GHz. Frequency Resolution: 1 Hz. Frequency Stability: ±7.5 ppm (0° to 55° C), ±3 ppm/year; (Option 1D5) ±0.05 ppm (0° to 55° C), ±0.5 ppm/year. Frequency Accuracy: ±10 ppm at 25° ±5° C. Power range: -85 to +10 dBm; (Option 075/014) -85 to +8 dBm. Power sweep range: 25 dB (typically 31 dB). Resolution: 0.01 dB. Level accuracy: ±1.0 dB. Level linearity: -15 dBm to +5 dBm ±0.2 dB, 5 dBm to 10 dBm ±0.5 dB. Impedance: 50 ohm (nom), 30 kHz to 3 GHz >16 dB RL (<1.38 SWR), 3 GHz to 6 GHz >14 dB RL (<1.50 SWR); (Option 075) 75 ohm (nom), 30 kHz to 3 GHz >16 dB RL (<1.38 SWR). Spectral purity 2nd harmonic: <-40 dBc at 0 dBm, <-50 dBc at -10 dBm; (Option 002) <-25 dBc at 10 dBm. Spectral purity 3rd harmonic: <-40 dBc at 0 dBm, <-50 dBc at -10 dBm; (Option 002) <-25 dBc at 10 dBm. Nonharmonic spurious (Mixer related): <-30 dBc at 10 dBm, <-55 dBc at -10 dBm. Average noise level (<3 GHz): <-82 dBm (3 kHz BW), <-102 dBm (10 Hz BW), <-110 dBm (10 Hz BW) typical. Average noise level (3 to 6 GHz): <-77 dBm (3 kHz BW), <-77 dBm (3 kHz BW), <-105 dBm (10 Hz BW) typical. Max input level: 10 dBm. Damage level: 26 dBm or 35 VDC. Impedance: 50 ohm (nom); Option 075 75 ohm (nom). Frequency response: 300 kHz to 3 GHz ±1.0 dB; 3 GHz to 6 GHz ±2.0 dB. Harmonic measurement accuracy: 300 kHz to 3 GHz ±1.5 dB; (Option 006) 3 GHz to 6 GHz ±3 dB. Magnitude Dynamic accuracy: (10 Hz IF BW). Display resolution: 0.001 dB/div. Number of display channels: 4. Measured number of points per sweep: Linear frequency: choose 3, 11, 26, 51, 101, 201, 401, 801, or 1601 points. Test Ports (Front Panel): Connector type 7 mm, precision; (Opt 011), Connector type Type-N female. GPIB interface. Options: (Opt 002, Harmonic measurements), Measures amplifier 2nd and 3rd harmonics on a swept-frequency basis for fundamental signals above 16 MHz. (Opt 006, 6 GHz operation). (Opt 010, Time domain), (Opt 1D5, High-stability frequency reference)



 

Standard Calibration $675.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 8753ES. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Average Power
Average power means that the energy transfer rate is to be averaged over many periods of the lowest frequency involved. For a CW signal, the lowest frequency and highest frequency are the same, so average power and power are the same. For an amplitude modulated wave, the power must be averaged over many periods of the modulation component of the signal as well.

Harmonic
A harmonic of a wave is a component frequency of the signal that is an integer multiple of the fundamental frequency, i.e. if the fundamental frequency is f, the harmonics have frequencies 2f, 3f, 4f, . . . etc.

Phase Noise
Phase noise is the frequency domain representation of rapid, short-term, random fluctuations in the phase of a waveform, caused by time domain instabilities. Phase noise (L(f)) is typically expressed in units of dBc/Hz, representing the noise power relative to the carrier contained in a 1 Hz bandwidth centered at a certain offsets from the carrier.


Please contact us for your Keysight (Agilent) 8753ES REPAIR and/or Keysight (Agilent) 8753ES S-parameter Network Analyzer CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: