Keysight (Agilent) 8756A REPAIR and Keysight (Agilent) 8756A CALIBRATION

 
Custom-Cal has a high success rate in the repair of the Keysight (Agilent) 8756A. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 8756A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Network Analyzer, SNA, VNA?
Shop for Comparable Products on our
 used Network Analyzer, SNA, VNA page or new Network Analyzer, SNA, VNA page

 
   Keysight (Agilent) 8756A   Description / Specification:    
Keysight (Agilent) 8756A Scalar Network Analyzer

The HP 8756A Scalar Network Analyzer, features two independent display channels with separate controls. Complete measurements can be performed using only five control keys for each channel. Measure insertion loss and gain, return loss, and absolute power quickly and accurately with the HP 8756A scalar network analyzer. These scalar measurements can be performed over a broad 10 MHz to 60 GHz frequency range. The HP 11664 diode detectors and AC modulation make accurate, reliable, and drift-free measurements. High-directivity directional bridges covering RF and microwave frequencies produce excellent reflection measurements. Since all of the controls of the HP 8756A are completely programmable, computer-controlled automatic systems can make full use of the HP 8756A and its built-in features. Specifications. Function: The HP 8756A processes and displays the demodulated 27.8 kHz signals from the HP 11664 detectors and the HP 85020 or 85027 bridges. Dynamic range: + 10 dBm to -50 dBm in all three inputs (A, B, and R) . Dynamic accuracy: dynamic accuracy of a single channel measurement using HP 11664A/D/E Detector. Measurement taken over + 10 to -50 dBm at 25°C and at 50 MHz; ±(0.1 dB + 0.01 dB/dB) from +10 to -40 dBm; ±(0.2 dB + 0.02 dB/dB) from -40 to -50 dBm. Scale resolution: 0.1,0.2,0.5, 1, 2,5, 10, or 20 dB per division. Independently controlled for each measurement channel. Reference oHset: offset level adjustable in 0.01 dB increments from -70.00 to +20.00 dBm (absolute) or-90.00 to +90.00 dB (ratio). Resolution Vertical: 0.006 dB for display; 0.01 dB for "Display Cursor." Horizontal: 401 points. Adjustable horizontal resolution (101, 201 or 401 points) is available as Option H20. Sweep time: minimum sweep time >= 150 ms (50 ms with Opt. H20) . Averaging: 2, 4, 8, 16,32,64, 128, or 256 traces may be averaged. Independent control of each display channel. Normalization: traces are stored and normalized to 0.006 dB resolution, independent of scale/ division or offset. The horizontal resolution is 401 points.



 

Standard Calibration $675.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 8756A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Dynamic range
Dynamic range the ratio of a specified maximum level of a parameter, such as power, current, voltage or frequency, to the minimum detectable value of that parameter.

Noise Floor
Noise floor is the measure of the signal created from the sum of all the noise sources and unwanted signals within a measurement system.

White Noise
White noise is noise whose power spectral density (watts/hertz) is constant for the frequency range of interest.


Please contact us for your Keysight (Agilent) 8756A REPAIR and/or Keysight (Agilent) 8756A Scalar Network Analyzer CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: