Keysight (Agilent) E2378A CALIBRATION and Keysight (Agilent) E2378A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) E2378A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Multimeter DMM?
Shop for Comparable Products on our
 used Multimeter DMM page

 
   Keysight (Agilent) E2378A   Description / Specification:    
Keysight (Agilent) E2378A 3 1/2-Digit Handheld Multimeter

The HP E2378A Digital Multimeter has a basic DCV accuracy of 0.3% and a 1 kHz bandwidth. It also adds a data hold function and a temperature function. Audible continuity and a choice of autoranging or manual ranging. The temperature function is built-in and can be used with any K-type thermocouple probe. The HP E2378A has a large 3200 count digital display (samples approx. 2 times/ sec.) with 32-segment analog bar (samples approx. 12 times / sec.). Specifications. Display count: 3200. Basic accuracy DC volts: 0.3%. Basic accuracy AC volts: 1%. Basic accuracy ohms: 0.7%. Maximum input: 1,000 V dc or 750 V ac rms. Maximum ac bandwidth: 1 kHz. DC volts Resolution/maximum reading: 100 µV / 1000 V. AC volts Resolution/maximum reading: 1 mV / 750 V. Ohms Resolution/maximum reading: 0.1 ohm / 30 M-ohm. Current Resolution/maximum reading: 100 nA / 10 A.



 

Standard Calibration $125.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) E2378A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBc
dBc (decibels relative to the carrier) is the power ratio of a signal to a carrier signal, expressed in decibels. If the dBc figure is positive, then the relative signal strength is greater than the carrier signal strength. If the dBc figure is negative, then the relative signal strength is less than carrier signal strength.

Load Regulation
Load regulation is the capability to maintain a constant voltage (or current) level on the output channel of a power supply despite changes in the supply's load (such as a change in resistance value connected across the supply output).

Power Linearity
When changing the power level and measuring the differences (in dB) between actual and displayed power levels, the power linearity is ± half the span (in dB) between the maximum and the minimum value of all differences.

Settling Time
Settling time of an output device is the time elapsed from the application of an ideal instantaneous step input to the time at which the amplifier output has entered and remained within a specified error band, usually symmetrical about the final value.


Please contact us for your Keysight (Agilent) E2378A CALIBRATION and/or Keysight (Agilent) E2378A 3 1/2-Digit Handheld Multimeter REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: