Custom-Cal has a high success rate in the repair of the Keysight (Agilent) E3640A. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) E3640A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another DC Power Supply?
Shop for Comparable Products on our
 used DC Power Supply page

 
   Keysight (Agilent) E3640A   Description / Specification:   Spec Sheet 
Keysight (Agilent) E3640A Single Output Dual-range DC Power Supply

The Agilent E3640A Single Output Dual-range DC Power Supply delivers clean and reliable power, dependable regulation (0.01%) and fast settling time (<90 msec). This linear power supply specifies both normal mode voltage noise and common mode current noise to assure less interference with your DUT. It comes with GPIB and RS-232. This allows you to program both voltage and current. You can monitor the output terminals for voltage and current, and a query command lets you read the programmed voltage and current. Both voltage and current can be monitored simultaneously for output from the front panel on an easy to read vacuum fluorescent display. A knob allows you to set the output at the resolution you need for the most exacting adjustments, quickly and easily. Voltage and current levels can be set to a maximum resolution of 10 mV/1mA from the front panel. Store and recall key enables you to save and recall up to 5 frequently used operating states. The output on/off button enables/disables the output. New front panel binding posts offer flexibility to use safety test leads, banana plugs or stripped wires. Specifications. DC Outputs: 0 to 8 V / 3 A or 0 to 20 V / 1.5 A. Power (max): 30 W. Load and Line Regulation (Voltage / Current): <0.01% + 3 mV / < 0.01% + 250 uA. Ripple and Noise (20 Hz to 20 MHz); Normal-Mode Voltage: <5 mVpp / 0.5 mVrms. Normal-Mode Current: < 4.0 mArms. Common-Mode Current: < 1.5 uArms. Programming Accuracy (Voltage / Current): 0.05% + 10 mV / 0.2% + 10 mA. Readback Accuracy (Voltage / Current): 0.05% + 5 mV / 0.15% + 5 mA. Program Resolution (Voltage / Current): 5 mV / 1 mA. Readback Resolution (Voltage / Current): 2 mV / 1 mA. Meter Resolution (Voltage / Current): 10 mV / 1 mA. Transient response time: <50 us for output to recover within 15 mV following a change in output current from full load to half load or vice versa.



 

Standard Calibration $95.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) E3640A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBm
dBm (sometimes dBmW) is an abbreviation for the power ratio in decibels (dB) of the measured power referenced to one milliwatt (mW). Zero dBm equals one milliwatt. A 3 dB increase represents roughly doubling the power, a 3 dB decrease, the power is reduced by about one half.

Millimeter-wave
Millimeter-wave is a term that generally refers to frequencies of 26.5 GHz and above. That is where signal wavelengths fall below approximately 10 mm, and thus the terminology changes from centimeters to millimeters.

Power Repeatability
Power Repeatability is the random uncertainty in reproducing the power level after changing and re-setting the power level. The power repeatability is ± half the span (in dB) between the highest and lowest actual power. Note: - The long-term power repeatability can be obtained by taken the power repeatability and power stability into account.

Stability
Stability is the extent to which a specified property, characteristic, or parameter of a substance, device, or apparatus, remains fixed with the passage of time or with varying environmental conditions.


Please contact us for your Keysight (Agilent) E3640A REPAIR and/or Keysight (Agilent) E3640A Single Output Dual-range DC Power Supply CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: