Keysight (Agilent) E4422B REPAIR and Keysight (Agilent) E4422B CALIBRATION

 
Custom-Cal has a high success rate in the repair of the Keysight (Agilent) E4422B. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) E4422B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Signal Generator?
Shop for Comparable Products on our
 used Signal Generator page

 
   Keysight (Agilent) E4422B   Description / Specification:    
Keysight (Agilent) E4422B ESG-A 4000 MHz Analog RF Signal Generator

The HP E4422B 250 kHz to 4000 MHz is an ESG-A analog series RF signal generator. Resolution: 0.01 Hz. Switching Speed Modulation On: < 45 ms, typical. Switching Speed Modulation Off: < 35 ms, typical. Accuracy: Stability x fc timebase. Sweep Operating modes: Step: frequency and power, and arbitrary list. Sweep Dwell Time: 1 ms to 60 sec. Number of points: 2 to 401. Internal Reference Oscillator; Timebase Reference Output Frequency: 10 MHz, Amplitude: > 0.35 Vrms into 50 ohm load. External Reference Input; Frequency: 1, 2, 5, 10 MHz ± typ. 10 ppm (1 ppm, Option 1E5), Amplitude: > 0.15 Vrms, Input Impedance: 50 ohm. Output Range: 250 kHz to 1000 MHz +13 to -136 dBm (+17 to -136 dBm Option UNB), > 1000 MHz to 3000 MHz +10 to -136 dBm (+16 to -136 dBm Option UNB), > 3000 MHz to 4000 MHz +7 to -136 dBm (+13 to -136 dBm Option UNB). Output Resolution: 0.02 dB. Attenuator Hold Level Range: > 17 dB (>23 dB Option UNB). Switching Speed: < 25 ms typical (30 ms, Option UNB). SSB Phase Noise (typical, at 20 kHz offset) at 4000 MHz: < -104 dBc/Hz. Harmonics (<= + 4 dBm [<= +7.5 dBm, Option UNB] output level): < - 30 dBc. Frequency Modulation; Maximum Deviation: N x10 MHz. Resolution: 0.1% of deviation or 1 Hz, whichever is greater. Deviation Accuracy (1 kHz rate, dev. < N x 100 kHz): < ± (3.5% of FM deviation + 20 Hz). Phase Modulation; Maximum Deviation: N x 90 radians. Resolution: 0.1% of set deviation. Deviation Accuracy (1 kHz rate): < ± (5% of deviation + 0.01 radians). Pulse Modulation; On/Off Ratio: <= 3 GHz: > 80 dB; > 3 GHz: > 60 dB. Rise/Fall Times: 150 ns, typical. Minimum Width (typical): ALC On: 2µs; ALC Off: 0.4µs. Level Accuracy (relative to CW)4 : ± 0.5 dB, typical. Internal Pulse Generator Squarewave Rates: 0.1 Hz-50 kHz. Pulse Period: 16 µs to 30 sec. Pulse Width: 8 µs to 30 sec. Interface: HP-IB (IEEE-488.2-1987) with Listen and Talk. RS-232. Options: 1EM, Move Connectors to Rear Panel. 1E5, Add High-Stability Timebase. UNB. High Power with mechanical attenuator



 

Standard Calibration $825.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) E4422B. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Average Power
Average power means that the energy transfer rate is to be averaged over many periods of the lowest frequency involved. For a CW signal, the lowest frequency and highest frequency are the same, so average power and power are the same. For an amplitude modulated wave, the power must be averaged over many periods of the modulation component of the signal as well.

Dynamic range
Dynamic range the ratio of a specified maximum level of a parameter, such as power, current, voltage or frequency, to the minimum detectable value of that parameter.

Modulation
Modulation is the process by which the characteristic of one wave (the carrier) is modified by another.

Repeatability
Repeatability is the variation in a number of repeated measured quantities when measurement conditions are changed and restored. The value corresponds to half the spread between the minimum and maximum value measured.


Please contact us for your Keysight (Agilent) E4422B REPAIR and/or Keysight (Agilent) E4422B ESG-A 4000 MHz Analog RF Signal Generator CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: