Keysight (Agilent) E5052A CALIBRATION and Keysight (Agilent) E5052A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) E5052A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Signal Analyzer?
Shop for Comparable Products on our
 used Signal Analyzer page

 
   Keysight (Agilent) E5052A   Description / Specification:   Spec Sheet 
Keysight (Agilent) E5052A 7 GHz Signal Source Analyzer

The Agilent E5052A 7 GHz Signal Source Analyzer is an all-in-one solution is optimized for efficient measurements, high reliability, and offers easy-to-use features to minimize training and increase productivity. The Signal Source Analyzer provides a true one-step phase noise measurement. Built-in low-noise reference sources, lock the system to the carrier of the measured signal, automatically enabling and dramatically improving measurement speed. With a frequency offset range between 1 kHz to 40 MHz, measurements only take 0.3 seconds per measurement. Dual channel receivers enable a “cross-correlation” technique to lower the instrument’s noise floor at all offset frequencies. Correlations of up to 10,000-times produces a 20 dB phase noise sensitivity improvement. Integrated phase noise between two points specified by the band marker function can be automatically calculated. Both rms jitter and residual FM are also displayed. Specifications. Frequency range: 10 MHz to 7 GHz. Input power level: -20 dBm to +20 dBm (RF input). Measurement Parameters: Frequency, RF power, and DC current. RF power Resolution: 0.01 dB. RF power Accuracy: ± 0.5 dB. Frequency Resolution: 10 Hz, 1 kHz, 64 kHz. Frequency Accuracy: ± (frequency resolution + time base accuracy). Phase noise Offset frequency range: 1 Hz to 40 MHz. Spectrum monitor: 15 MHz max Span, RBW = 1 Hz to 100 kHz. DC sources Control voltage: -15 to +35 volt, 20 mA max. Display Size: 10.4 in TFT color LCD. Options. 011, Delete functions. 012, Add standard functions. 018, Add hard disk drive kit.



 

Standard Calibration $1,060.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) E5052A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBm
dBm (sometimes dBmW) is an abbreviation for the power ratio in decibels (dB) of the measured power referenced to one milliwatt (mW). Zero dBm equals one milliwatt. A 3 dB increase represents roughly doubling the power, a 3 dB decrease, the power is reduced by about one half.

Millimeter-wave
Millimeter-wave is a term that generally refers to frequencies of 26.5 GHz and above. That is where signal wavelengths fall below approximately 10 mm, and thus the terminology changes from centimeters to millimeters.

Power Repeatability
Power Repeatability is the random uncertainty in reproducing the power level after changing and re-setting the power level. The power repeatability is ± half the span (in dB) between the highest and lowest actual power. Note: - The long-term power repeatability can be obtained by taken the power repeatability and power stability into account.

Stability
Stability is the extent to which a specified property, characteristic, or parameter of a substance, device, or apparatus, remains fixed with the passage of time or with varying environmental conditions.


Please contact us for your Keysight (Agilent) E5052A CALIBRATION and/or Keysight (Agilent) E5052A 7 GHz Signal Source Analyzer REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: