Keysight (Agilent) E8357A REPAIR and Keysight (Agilent) E8357A CALIBRATION

 
Custom-Cal has a high success rate in the repair of the Keysight (Agilent) E8357A. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) E8357A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Network Analyzer, SNA, VNA?
Shop for Comparable Products on our
 used Network Analyzer, SNA, VNA page or new Network Analyzer, SNA, VNA page

 
   Keysight (Agilent) E8357A   Description / Specification:    
Keysight (Agilent) E8357A 6 GHz PNA Vector Network Analyzer

The Agilent E8357A 6 GHz PNA vector network analyzer offers unparalleled measurement capabilities. Using the widest bandwidth and 1601 points, you get measurements at 35 µs/point. This speed does not come at the expense of trace noise. The 35 kHz IF bandwidth boasts an impressively low trace noise of 0.004 dB RMS. The result is very accurate measurements of low-loss devices. With direct access to measurement receivers, you can measure up to 143 dB of dynamic range. This increased measurement range enables clear, precise measurements of base station filters or LNA receiver/filter combinations. The PNA E8356A provides additional accuracy through TRL/TRM calibration. The series uses four mixer-based receivers so you can utilize true TRL/TRM calibration for accurate in-fixture and onwafer measurements. The time-domain option (Option 010) allows you to locate and resolve discontinuities in devices, fixtures, or cables. Once located, unwanted responses can be removed using the gating function. Option 010 also furnishes a very simple and deterministic technique to tune cavity-resonator filters. Option 015 provides a configurable test set for maximum flexibility. Front panel access to the RF signal path allows for customization within the test set. Specifications. Frequency Range: 300 kHz to 6 GHz. Impedance: 50 ohms. Test Port Connector: Type-N (female). Frequency Resolution: 1 Hz. Trace Noise 1 kHz IF BW (Magnitude / Phase): <0.002 dB rms / < 0.010° rms. Trace Noise 10 kHz IF BW (Magnitude / Phase): <0.005 dB rms / < 0.035° rms. Source Power Range: –85 to +10 dBm. Power Resolution: 0.05 dB. Power Level Linearity: ±0.3 dB. Power Sweep Range: 25 dB. System Dynamic Range At test port: 125 db (300 kHz to 25 MHz), 128 db (25 MHz to 3 GHz), 118 db (3 GHz to 6 GHz). Options. Opt 010, Time Domain. Opt 015, Configurable Test Set. Opt AM8, Add CD R/W Drive. Opt B30, Add USB Hub.



 

Standard Calibration $905.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) E8357A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Available Gain
Available Gain is the ratio, at a specific frequency, of power available from the output to the power in from the source.

Frequency Span
Frequency Span specifies the range between the start and stop frequencies, also referred to as bandwidth

Peak Envelope Power
Peak envelope power is the maximum value of the envelope power. Envelope power is measured by making the averaging time much less than 1/fm where fm is the maximum frequency component of the modulation waveform. The averaging time is therefore limited on both ends: (1) it must be small compared to the period of the highest modulation frequency, and (2) it must be large enough to be many RF cycles long.


Please contact us for your Keysight (Agilent) E8357A REPAIR and/or Keysight (Agilent) E8357A 6 GHz PNA Vector Network Analyzer CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: