Keysight (Agilent) E8358A CALIBRATION and Keysight (Agilent) E8358A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) E8358A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Network Analyzer, SNA, VNA?
Shop for Comparable Products on our
 used Network Analyzer, SNA, VNA page or new Network Analyzer, SNA, VNA page

 
   Keysight (Agilent) E8358A   Description / Specification:    
Keysight (Agilent) E8358A 9 GHz PNA Vector Network Analyzer

The Agilent E8358A 9 GHz PNA vector network analyzer offers unparalleled measurement capabilities. Using the widest bandwidth and 1601 points, you get measurements at 35 µs/point. This speed does not come at the expense of trace noise. The 35 kHz IF bandwidth boasts an impressively low trace noise of 0.004 dB RMS. The result is very accurate measurements of low-loss devices. With direct access to measurement receivers, you can measure up to 143 dB of dynamic range. This increased measurement range enables clear, precise measurements of base station filters or LNA receiver/filter combinations. The PNA E8356A provides additional accuracy through TRL/TRM calibration. The series uses four mixer-based receivers so you can utilize true TRL/TRM calibration for accurate in-fixture and onwafer measurements. The time-domain option (Option 010) allows you to locate and resolve discontinuities in devices, fixtures, or cables. Once located, unwanted responses can be removed using the gating function. Option 010 also furnishes a very simple and deterministic technique to tune cavity-resonator filters. Option 015 provides a configurable test set for maximum flexibility. Front panel access to the RF signal path allows for customization within the test set. Specifications. Frequency Range: 300 kHz to 9 GHz. Impedance: 50 ohms. Test Port Connector: Type-N (female). Frequency Resolution: 1 Hz. Trace Noise 1 kHz IF BW (Magnitude / Phase): <0.002 dB rms / < 0.010° rms. Trace Noise 10 kHz IF BW (Magnitude / Phase): <0.005 dB rms / < 0.035° rms. Source Power Range: –85 to +10 dBm (300 kHz to 6 GHz), –85 to +5 dBm (6 GHz to 9 GHz). Power Resolution: 0.05 dB. Power Level Linearity: ±0.3 dB. Power Sweep Range: 25 dB (300 kHz to 6 GHz), 20 dBm (6 GHz to 9 GHz).. System Dynamic Range At test port: 125 db (300 kHz to 25 MHz), 128 db (25 MHz to 3 GHz), 118 db (3 GHz to 6 GHz), 113 db (6 GHz to 9 GHz). Options. Opt 010, Time Domain. Opt 015, Configurable Test Set. Opt AM8, Add CD R/W Drive. Opt B30, Add USB Hub.



 

Standard Calibration $785.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) E8358A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBc
dBc (decibels relative to the carrier) is the power ratio of a signal to a carrier signal, expressed in decibels. If the dBc figure is positive, then the relative signal strength is greater than the carrier signal strength. If the dBc figure is negative, then the relative signal strength is less than carrier signal strength.

Noise Density
Noise Density is the amount of noise within a defined bandwidth, usually normalized to 1 Hz.

Spurious Signals
Spurious signals are undesired signals. They can be considered in two classes. They can be stationary; their frequency and amplitude do not change significantly, or non-stationary, where the frequency and/or amplitude change significantly over short time periods.


Please contact us for your Keysight (Agilent) E8358A CALIBRATION and/or Keysight (Agilent) E8358A 9 GHz PNA Vector Network Analyzer REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: