Keysight (Agilent) MSO6034A CALIBRATION and Keysight (Agilent) MSO6034A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) MSO6034A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope?
Shop for Comparable Products on our
 used Oscilloscope page

 
   Keysight (Agilent) MSO6034A (MS06034A)   Description / Specification:    
Keysight (Agilent) MSO6034A 4+16 Ch 300 MHz InfiniiVision Mixed Signal Oscilloscope

The Agilent MSO6034A InfiniiVision 300 MHz, 4 analog, 16 digital channel oscilloscope is equipped with a 6.3” XGA LCD display, comes in a whisper-quiet package that weighs only 11 pounds. The InfiniiVision 6000 Series shows jitter, infrequent events, and subtle signal detail that other scopes miss. Turn knobs and the instrument responds instantly and effortlessly. InfiniiVision scopes incorporate acquisition memory, waveform processing, and display memory in an advanced 0.13 µ ASIC. This patented 3rd generation technology, known as MegaZoom III, delivers up to 100,000 waveforms (acquisitions) per second with responsive deep memory always available. Specifications. Bandwidth: 300 MHz. Sample rate: 2 GSa/sec each channel. Maximum memory depth 2 channels/4 channels: 8 Mpts/4 Mpts. Input channels: 4 analog + 16 digital. Vertical resolution. 8 bits. Peak detection: 500-ps peak detect. Averaging Selectable from: 2, 4, 8, 16, 32, 64 ... to 65536. High resolution mode: Average mode with avg = 1, 12 bits of resolution when >=10 µs/div @ 4 GSa/s or >=20 µs/div @ 2 GSa/s. Acquisition digital channels; Sample rate: 2 GSa/sec one pod, 1 GSa/sec each pod. Maximum input frequency: 250 MHz. Maximum memory depth: One pod/both pods (with scope channels turned off), 8 Mpts/4 Mpts. Vertical resolution: 1 bit. Glitch detection: 2 ns (min pulse width). Vertical system scope channels; Scope channels: Ch 1, 2, 3 and 4 simultaneous acquisition. Bandwidth (–3dB): DC to 300 MHz. Calculated rise time (=0.35/bandwidth): 1.17 nsec. Single-shot bandwidth: 300 MHz. Range: 2 mV/div to 5 V/div (1 Mohm or 50 ohm). Maximum input: CAT I 300 Vrms, 400 Vpk; transient overvoltage 1.6 kVpk. Vertical system digital channels; Number of channels: 16 logic timing channels – labeled D15 - D0. User-defined threshold range: ±8.0 V in 10 mV increments. Maximum input voltage: ±40 V peak CAT I; transient overvoltage 800 Vpk. Threshold accuracy: ±(100 mV + 3% of threshold setting). Input dynamic range: ±10 V about threshold. Minimum input voltage swing: 500 mV peak-to-peak. Horizontal; Range: 2 nsec/div to 50 sec/div. Resolution: 2.5 psec. Time scale accuracy: <= ± (15 + 2*(instrument age in years)) ppm.



 

Standard Calibration $460.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) MSO6034A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Crest Factor
Crest factor or peak-to-average ratio (PAR) is a measurement of a waveform, calculated from the peak amplitude of the waveform divided by the RMS value of the waveform

Linearity
Linearity is the relative difference between the displayed power ratio, Dx/D0, and the actual (true) power ratio Px/P0 caused by changing the displayed power level from the reference level, D0, to an arbitrary displayed level, Dx.

Phase Noise
Phase noise is the frequency domain representation of rapid, short-term, random fluctuations in the phase of a waveform, caused by time domain instabilities. Phase noise (L(f)) is typically expressed in units of dBc/Hz, representing the noise power relative to the carrier contained in a 1 Hz bandwidth centered at a certain offsets from the carrier.

Sensitivity
Sensitivity is the minimum magnitude of input signal required to produce a specified output signal having a specified signal-to-noise ratio, or other specified criteria.


Please contact us for your Keysight (Agilent) MSO6034A CALIBRATION and/or Keysight (Agilent) MSO6034A 4+16 Ch 300 MHz InfiniiVision Mixed Signal Oscilloscope REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: